Basic Info.
Type
Veterinary X Machine
Syringe
Continuous Syringe
Blood Sampling Needle
Disposable Vacuum Blood Sampling
Breathing Pattern
Manual Mode
Animal Anesthesia Machine Control Method
Electronic Control
Power Supply
AC100-240V, 50/60Hz, 30va
Data Storage
3000 Results
Display
12 Inch LCD Screen
Storage Temperature
-20ºC~60ºC
Basic Parameters
ECG, Temp, SpO2, Resp, NIBP
Specification
side stream or main stream
Product Description
Product Description
Purpose:
ETCO2 is the amount of carbon dioxide (CO2) in exhaled air, which assesses ventilation.
Product Details:
Inspect of ventilation
This highly advanced module of EtCO2 is designed to be easy to use and deliver consistently accurate vital signs information every single time it's used. Whether you need to monitor the exhaled breath of a patient under general anesthesia, or you are interested in having an end tidal CO2 monitor on hand to identify ventilation-related problems before they become more serious, we are able to assist. A high ETCO2 is a good sign of good ventilation, while low ETCO2 is bad sign that represents hypoventilation.Reliable filter cells
Features reliable filter cells that help prevent contamination, ensuring the data is as accurate as possible Easy to install
Plug and play: no need to occupy the host space, the host only needs a socket and a serial port to realize the connection. It is highly portable and can be transported together with medical patient monitor if necessary. Connection method
Connect the sampling tube nasal tube/airway of anesthesia machine through dehydrating bottle. Easy to identify various anesthetic reagents
The module of EtCO2 can identify various anesthetic reagents automatically. Built in compensation program of anesthetic gas, nitrous oxide and other gases interfering with CO2 measurement.
Specification
ECG | TEMP |
Lead mode | 3-Lead: I, II, III, 5-Lead: I, II, III, aVR, aVL, aVF, V | Measurement method: | Thermal resistance |
Waveform speed: | 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s | Measurement range: | 0.0°C to 50.0°C |
Display sensitivity: | 2.5mm/mV(×0.25), 5mm/mV(×0.5), 10mm/mV(×1), 20mm/mV (×2) | Resolution: | 0.1°C |
Heart rate measurement range: 15bpm to 350bpm | Accuracy (without sensor): | ±0.1°C |
| | | |
RESP | | SpO2 | |
Measurement method: | Trans-thoracic impedance | Measurement range: | 0 to 100% |
Measurement lead: | Lead Options are lead I and II. The default lead is lead II. | Accuracy: | ±2% (70% to 100% SpO2) |
Respiratory rate (RR) | | Undefined (0 to 69% SpO2) | |
Measurement range: | 0 to 150 rpm | Pulse Rate | |
Accuracy: | ±2 rpm | Measurement range: | 200 bpm to 300 bpm |
| | Resolution: | 1 bpm |
NIBP | | Accuracy | ±3bpm |
Measurement method: | Oscillometric | |
Mode: | Manual, Auto, Continous | 2IBP (Optional) |
Measuring type: | SYS, DIA, MAP, PR | Channels: | 2-6 optional |
NIBP measurement range: | SYS: 40mmHg to 270mmHg; DIA: 10mmHg to 215mmHg; MAP: 20mmHg to 235 mmHG | Range: | 50 to 300 mmHg |
Maximum mean error: | ±5 mmHg | Accuracy: | ±1 mmHg or ±2% |
Maximum standard deviation: | 8mmHg | IBP label: | Utsh, Edeard, Abbott |
| | Speed: | 12.5mm/s, 25mm/s, 50mm/s |
| | Width: | 48mm |
| | | |
| | EtCO2 (Optional) | |
| | Type: | Sidestream and Mainstream |
| | Measurement range: | 0% to 20% (0 mmHg to 150mmHg) |
| | Measurement accuracy: | <5.0% CO2:±2mmHg |
| | >5.0% CO2:<6% of the readings |
| | AwRR measurement range: | 3 rpm to 150 rpm |
| | AwRR measurement accuracy: | ±1 rpm or ±1% whichever is greater |
Detailed Photos
Company Profile
Jiangsu MongGo Animal Bio-Medical Technology Co., Ltd (the subsidiary company of Jiangsu Konsung Biomedical Science and Technology Co., Ltd) was founded in 2016. This is a national high-tech enterprise which contributes to the research, development, manufacture, sale and service of in vitro rapid diagnosis products.
Mongo concentrates on the rapid diagnosis of human and animal infectious diseases, and provides veterinary oxygen concentrator, patient monitor and POCT analyzer etc. The products of our company are selling in over 130 countries and regions worldwide. It is widely used in animal medical treatment market (including companion animals farm…) and other fields.
FAQ
1. What causes an increase in ETCO2?
In severe cases of respiratory distress, increased effort to breathe does not effectively eliminate CO2. This causes CO2 to accumulate in the lungs and more of it to be excreted with each breath (hypercapnia), which would cause the ETCO2 level to rise.
2. What conditions increase ETCO2 what conditions decrease ETCO2?
Hypoventilation (reduced minute ventilation) causes an increase in EtCO2. Hyperventilation (excess minute ventilation) causes a decrease in EtCO2.
3. Why does hyperventilation cause low ETCO2?
Increased work of breathing from pulmonary edema may lead to fatigue and respiratory failure. This would cause a rise in ETCO2, but the waveform will remain upright. Hyperventilation causes excess CO2 to be exhaled, which would present with a crisp waveform and low ETCO2, or hypocapnia.
4. Why is paco2 higher than ETCO2?
The PaCO2 - EtCO2 gradient is largely dependent on the physiological dead space and the slope of the alveolar plateau in phase 3 of the capnograph. An increase in the dead space can result in an increase in the gradient.
5. What are normal EtCO2 levels?
End-tidal CO2 (EtCO2) monitoring is a noninvasive technique which measures the partial pressure or maximal concentration of carbon dioxide (CO2) at the end of an exhaled breath, which is expressed as a percentage of CO2 or mmHg. The normal values are 5% to 6% CO2, which is equivalent to 35-45 mmHg.
Address:
No. 8, Shengchang West Road, Danyang Development Zone, Zhenjiang, Jiangsu, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Agriculture & Food, Health & Medicine
Management System Certification:
ISO 9000
Company Introduction:
Licensed project: Veterinary drug production; Animal diagnosis and treatment; Production of class II medical devices (items that must be approved according to law can only be carried out after being approved by relevant departments, and the specific business items shall be subject to the approval results)
General projects: Research and development of bio based materials technology; Urban pet services (excluding animal diagnosis and treatment); Production of class I medical devices; Pet services (excluding animal diagnosis and treatment); Import and export of goods; Technology import and export; Import and export agency (except for projects that must be approved according to law, carry out business activities independently by virtue of business license according to law)
Jiangsu MongGo Animal Bio-Medical Technology Co., Ltd (the subsidiary company of Jiangsu Konsung Biomedical Science and Technology Co., Ltd) was founded in 2016. Mongo is a national high-tech enterprise which contributes to the research, development, manufacture, sale and service on the rapid diagnosis of human and animal infectious diseases, and provides veterinary oxygen concentrator, patient monitor and POCT analyzers etc. The products of our company are selling in over 130 countries and regions worldwide, universally used in human medical treatment market (including primary medical treatment, clinical examination, auxiliary surveillance of epidemic situation) and animal medical treatment market (including companion animals, farm animals and so on) and other fields.